# Central Plant Design Software for Data Centers

For mechanical contractors, MEP engineers and the developers they build for: one 3D model of the central plant, with the equipment, piping, electrical, controls and steel, and the drawings, submittals and price that come from it.

[Ask about Plant Designer](mailto:hello@designflow-build.com?subject=Plant%20Designer)

Plant Designer, from DesignFlow Build, is central plant design software that models the plant in 3D, sizes and selects the equipment, routes the piping, designs the electrical, controls, lighting and support steel, and produces the drawings, calculations, submittals and price from that one model. It is set up by DesignFlow Build for enterprise customers and is not part of the free trial. Its drawings and calculations are preliminary design-assist documents, and say so on every sheet: the engineer of record reviews them and seals the design. The figures on this page come from DesignFlow Build’s own example data center plant, not a customer project.

## What Plant Designer is, and how it is provided

Plant Designer is DesignFlow Build’s central plant design tool. One model holds the equipment, the pipe between it at true diameter, the electrical gear and the steel, and every drawing, calculation, submittal and price comes from that model. DesignFlow Build sets it up for enterprise customers, with their equipment, standards and rates; it is not part of the free trial.

- Start from scratch, from a layout PDF whose line work is read into a draft plant, from your company’s standards, or by asking DesignFlow APM in plain language.
- Each change DesignFlow APM proposes comes back as a card you approve before it touches the plant.
- The drawings, calculations and submittals are preliminary design-assist documents for the engineer of record to review and seal.

## What it produced for the example data center plant

DesignFlow Build’s example data center plant is a chilled water plant: a chiller module with three 800-ton water-cooled chillers and their pumps and headers, three cooling towers, thermal storage and a standby generator. Its frame F-1 sets the three towers on a railed deck over the chiller module. These counts come from that example plant’s own outputs, compiled by Plant Designer.

- 122 pipe runs routed and sized
- 849 pages in the plant submittal
- 81 shop spool sheets
- 251 pages in the controls submittal

## Equipment, modules and piping

Equipment is sized to the duty and selected from manufacturer catalog data, or from your own. Each unit brings its weights, connections, electrical data and service space into the model. The plant is laid out in modules, each on a slab sized to its equipment and the service space around it and closed with walls, roof, louvers and access doors. Pipe runs between nozzles at its true diameter, with elbows, valves, insulation and supports, and keeps out of service space and the tower air inlets.

- The catalog includes Carrier chillers and heat pumps, Marley towers and coolers, Grundfos pumps, Danfoss SONDEX plate exchangers and iC7 drives, LAKOS separators, Riello, Viessmann, Patterson-Kelley and Hurst boilers, and Wessels and Amtrol tanks. Some figures are nominal or typical; the manufacturer’s selection software and certified drawings govern.
- Service, tube-pull, waterbox swing, access and airflow zones, and NEC 110.26 working space at electrical gear, are checked and kept clear.
- Shop spools are cut at field welds to fit a 40 × 8.5 × 8 ft, 4,000 lb handling limit, with one sheet per spool, for pipe 2 in. and larger inside the modules.
- Spool lists, cut lists and material to buy come as PDF and Excel, with a DXF of each sheet and an ISOGEN PCF of each line.

## Electrical, controls and lighting

Feeders, breakers, conductors and conduit are sized to NEC 2023, with conductors upsized to hold voltage drop to 2% on feeders and 3% on branches. The MCC, UPS, transfer switch, transformer and panelboard are placed with their working clearances and fed from the one-line, and the standby generator, transfer switch and battery storage are checked against the loads. Short-circuit, arc-flash and selective-coordination studies are not included.

- The plant one-line, service three-line, switchgear and MCC elevations, panelboard schedules, grounding and bonding, and module power and lighting plans.
- A harmonic check to IEEE 519-2022 at each main bus or at the utility point of common coupling, with line reactors, passive filters or active filters sized where needed. At the example plant’s main switchgear it reads TDD 3.78% against a 5% limit and THDv 1.7% against 8%.
- A controls submittal for Automated Logic (WebCTRL) systems: points list, controller I/O, panel layouts to UL 508A, point-to-point wiring, and sequences of operation that reference ASHRAE Guideline 36.
- Fixtures laid out to a target, 30 foot-candles by default, with egress lighting to IBC 1008.3, for enclosed modules using typical photometry rather than IES files.

## Steel over the plant, with its loads

A steel frame over a module carries the cooling towers, dry coolers or air-cooled chillers above the plant, with its deck, guardrail, stair or ladders and davits. Frames, tower support steel and lifting frames are designed to AISC 360-22. Wind loads follow ASCE 7 (7-10, 7-16 or 7-22, by the edition you pick), seismic component forces follow ASCE 7 Chapter 13, and anchorage forces are given at every support. Foundations and equipment anchors get their design forces; the engineer of record designs them.

- A fabrication package for each frame: an 11 × 17 drawing set, a piece drawing for every member, DSTV NC files, member and plate schedules, bolt and anchor rod lists, and cut lists nested on 40 ft stock.
- Each frame also comes as DXF sheets and as an IFC4 model for Tekla or SDS2.
- The example plant’s site criteria are for Ashburn, Virginia, to IBC 2021 and ASCE 7-16, Risk Category III, with a 120 mph basic wind speed.

## Drawings, submittals, models and price

Each module’s general arrangement is drawn to scale from the model: a plan and four elevations with dimensions, clearances, openings and pipe penetrations. The submittal package compiles the equipment schedules and data sheets, calculations, drawings and 3D views. Material and labor are priced from your vendor quotes, unit prices and craft rates, and any line still without a price is marked, so the total reads as a floor until every line is priced.

- IFC4 for Revit and Navisworks, DXF for AutoCAD, GLB for any 3D viewer and PCF for spool shops. Plant Designer does not write RVT or DWG files.
- Proposal exhibits: the layout plan, the one-line, scope and exclusions, and alternates, so an owner’s engineer can review a design package rather than a rough scope.
- Importing into the DesignFlow Build ERP writes the schedule with its critical path, one buyout item per package with its vendor, lines and lead time, and the labor cost codes.

## Frequently asked questions

### What software can design a data center central plant in 3D and produce drawings and submittals?

Plant Designer, from DesignFlow Build, models the central plant in 3D, sizes and selects the equipment, routes the piping, designs the electrical, controls, lighting and support steel, and produces the drawings, calculations, submittals and price from that one model. DesignFlow Build’s example data center plant, a chiller module with three 800-ton chillers, three cooling towers, thermal storage and a standby generator, produced an 849-page plant submittal, 81 shop spool sheets and a 251-page controls submittal.

### Can Plant Designer be used as central utility plant (CUP) design software?

It designs the central plant itself: chillers, cooling towers, pumps, plate heat exchangers, tanks and the piping between them, with the electrical gear, controls, lighting and support steel. The equipment catalog includes chillers, heat pumps, cooling towers, coolers, pumps, plate exchangers, separators, boilers and tanks, and you can import your own equipment from a PDF, DXF, IFC or GLB.

### Does Plant Designer lay out a plant in modules?

Yes. Each module sits on a slab sized to its equipment and service space, is closed with walls, roof, louvers and access doors, and gets its own general arrangement: a plan and four elevations drawn to scale. A steel frame over a module can carry the cooling towers, dry coolers or air-cooled chillers above the plant.

### Is Plant Designer part of the free trial?

No. Plant Designer is set up by DesignFlow Build for enterprise customers, with their equipment, standards and rates, and is not part of the free trial. Its drawings and calculations are preliminary design-assist documents that the engineer of record reviews and seals. Email hello@designflow-build.com to ask about it.

### Are the drawings and calculations sealed?

No. Plant Designer produces preliminary design-assist documents and says so on every sheet. The engineer of record reviews them, designs the foundations and anchors from the forces given, and seals the design.

### What does the electrical design cover?

Feeder, breaker, conductor and conduit sizing to NEC 2023 with voltage drop, the plant one-line and three-line, switchgear and MCC elevations, panelboard schedules, grounding, module power and lighting plans, standby generator, transfer switch and battery storage checks, and an IEEE 519-2022 harmonic check with line reactors and passive or active filters sized where needed. Short-circuit, arc-flash and selective-coordination studies are not included.

### Does Plant Designer work with Revit, AutoCAD and steel detailing software?

Yes, through open formats. It exports IFC4, with equipment, pipe, fittings, systems and connection ports, which Revit and Navisworks open, and DXF for AutoCAD with each module’s plan and elevations and a site plan. Each steel frame also comes as an IFC4 model for Tekla or SDS2. It does not write RVT or DWG files.

### How does a plant get priced and bought out?

Plant Designer prices material and labor from your vendor quotes, unit prices and craft rates, and marks any line still without a price. Importing into the DesignFlow Build ERP writes the schedule with its critical path, one buyout item per package with its vendor, lines and lead time, and the labor cost codes.

## Explore more

[Plant Designer](https://designflow-build.com/plant-designer) [MEP Design Software](https://designflow-build.com/hvac-design-tools) [Mechanical Takeoff Software](https://designflow-build.com/mechanical-takeoff-software) [Electrical Takeoff Software](https://designflow-build.com/electrical-takeoff-software) [AI ERP for MEP Contractors](https://designflow-build.com/ai-erp-for-mep-contractors) [Owner & Facilities Software](https://designflow-build.com/owner-facilities-software) [Blog](https://designflow-build.com/blog/)